Path 3 of Microwave License WPNN969

⇠ Return to the list of all paths for Microwave License WPNN969

Path 3:   CAMDEN ⇢ Campbellstown

Transmit and Receive Locations

CAMDEN

Radio ServiceMG - Microwave Industrial/Business Pool
Transmit LocationCAMDEN
Transmitter CallsignWPNN969
TypeTransmitter
Height to Center134.8ft / 41.1m
Antenna MakeRFS
Antenna ModelPAL8-65A
PolarizationH
Tilt0.0°
Gain42.4dBi
Beamwidth1.3°
Azimuth348.3°
Location TypeFixed
Location ClassTransmit Location
Address2.6 MI SW OF INTER US 127 & HWY 725 NEAR
CityCAMDEN
CountyPREBLE
StateOH
Elevation (AMSL)1,100.1ft / 335.3m
Height of Structure154.9ft / 47.2m
Overall Height154.9ft / 47.2m
Lat / Lon39-36-22.10 N, 084-41-39.30 W

1: CAMDEN - Campbellstown

Segment Length12.287761mi / 19.775241km
Receive LocationCampbellstown
Receiver CallsignWPNN967
TypeReceiver
Height to Center159.8ft / 48.7m
Antenna MakeRFS
Antenna ModelPAL8-65A
Gain42.4°
Beamwidth1.3°
Diversity Height139.8ft / 42.6m
Diversity Gain39.9°
Diversity Beamwidth1.7°
Location ClassReceive Location
Elevation (AMSL)1,200.1ft / 365.8m
Lat / Lon39-46-50.10 N, 084-44-26.80 W

 

Frequencies and Modulations

FrequenciesToleranceEIRPATPCEmission, Digital Mod Rate, Digital Mod TypeTransmitter MakeTransmitter Model
1: 6226.890000000.00100%68.9dBmN30M0D7W, 190700.0, 256 QAM
ALCATEL LUCENT USA, INC95MPR61-L256F30-191-H