Path 2 of Microwave License WPSF649
⇠ Return to the list of all paths for Microwave License WPSF649
Path 2:
Seton Hospital ⇢ Thayer Hospital
Transmit and Receive Locations
Seton Hospital
Radio Service | MG - Microwave Industrial/Business Pool |
Transmit Location | Seton Hospital |
Transmitter Callsign | WPSF649 |
Type | Transmitter |
Height to Center | 128.9ft / 39.3m |
Antenna Make | Microwave Radio Corp. |
Antenna Model | MR-23VX (2FT) |
Polarization | V |
Tilt | 0.0° |
Gain | 40.0dBi |
Beamwidth | 1.8° |
Azimuth | 28.9° |
Location Type | Fixed |
Location Class | Transmit Location |
Address | Seton Hospital |
City | Waterville |
County | KENNEBEC |
State | ME |
Elevation (AMSL) | 220.1ft / 67.1m |
Height of Structure | 131.9ft / 40.2m |
Overall Height | 131.9ft / 40.2m |
Structure Type | BTWR - Building with Tower |
Lat / Lon | 44-32-57.20 N, 069-39-32.20 W |
1: Seton Hospital - Thayer Hospital
Segment Length | 1.248733mi / 2.009641km |
Receive Location | Thayer Hospital |
Receiver Callsign | WNTU626 |
Type | Receiver |
Height to Center | 62.0ft / 18.9m |
Antenna Make | Microwave Radio Corp. |
Antenna Model | MR-23VX (2FT) |
Gain | 40.0° |
Beamwidth | 1.8° |
Location Type | Fixed |
Location Class | Receive Location |
Elevation (AMSL) | 141.1ft / 43.0m |
Lat / Lon | 44-33-54.20 N, 069-38-48.20 W |
Frequencies and Modulations
Frequencies | Tolerance | EIRP | ATPC | Emission, Digital Mod Rate, Digital Mod Type | Transmitter Make | Transmitter Model |
1: 23375.00000000 | 0.03000% | 51.7dBm | N | 25M0F8W
| Microwave Radio Corp. | MR23VX |
|