Path 1 of Microwave License WQDB564
⇠ Return to the list of all paths for Microwave License WQDB564
Path 1:
CAMDEN RD ⇢ COLE MILL
Transmit and Receive Locations
CAMDEN RD
| Radio Service | MW - Microwave Public Safety Pool |
| Transmit Location | CAMDEN RD |
| Transmitter Callsign | WQDB564 |
| Type | Transmitter |
| Height to Center | 109.9ft / 33.5m |
| Antenna Make | ANDREW CORPORATION |
| Antenna Model | PL4-107E |
| Polarization | V |
| Tilt | 0.5° |
| Gain | 40.5dBi |
| Beamwidth | 1.6° |
| Azimuth | 285.0° |
| Location Type | Fixed |
| Location Class | Transmit Location |
| Address | 1811 CAMDEN AVE |
| City | DURHAM |
| County | DURHAM |
| State | NC |
| Elevation (AMSL) | 357.6ft / 109.0m |
| Tower Registration Number | 1058762 |
| Height of Structure | 479.0ft / 146.0m |
| Overall Height | 498.7ft / 152.0m |
| Structure Type | GTOWER - Guyed Structure Used for Communication Purposes |
| Lat / Lon | 36-01-11.00 N, 078-52-06.00 W |
1: CAMDEN RD - COLE MILL
| Segment Length | 5.216096mi / 8.394496km |
| Receive Location | COLE MILL |
| Type | Receiver |
| Height to Center | 134.8ft / 41.1m |
| Antenna Make | ANDREW CORPORATION |
| Antenna Model | PL4-107E |
| Gain | 40.5° |
| Beamwidth | 1.6° |
| Location Type | Fixed |
| Location Class | Receive Location |
| Elevation (AMSL) | 549.9ft / 167.6m |
| Lat / Lon | 36-02-21.40 N, 078-57-29.90 W |
Frequencies and Modulations
| Frequencies | Tolerance | EIRP | ATPC | Emission, Digital Mod Rate, Digital Mod Type | Transmitter Make | Transmitter Model |
| 1: 11628.12500000 | 0.00100% | 55.7dBm | N | 3M50D7W, 14420.0, 32QAM
| MICROWAVE NETWORKS INC | LBW-CM11HC-MDS1 |
|