Path 9 of Microwave License WQPD488

⇠ Return to the list of all paths for Microwave License WQPD488

Path 9:   TRO ⇢ ENT-Milan Institute

Transmit and Receive Locations

TRO

Radio ServiceMG - Microwave Industrial/Business Pool
Transmit LocationTRO
Transmitter CallsignWQPD488
TypeTransmitter
Height to Center15.1ft / 4.6m
Antenna MakeRADIO WAVES, INC
Antenna ModelHP3-11
PolarizationH
Tilt-1.3°
Gain38.5dBi
Beamwidth2.1°
Azimuth267.6°
Location TypeFixed
Location ClassTransmit Location
AddressTABLE ROCK TOWER
CityBOISE
CountyADA
StateID
Elevation (AMSL)3,645.0ft / 1,111.0m
Height of Structure85.0ft / 25.9m
Overall Height85.0ft / 25.9m
Structure TypeLTOWER - Lattice Tower
Lat / Lon43-35-43.60 N, 116-08-43.90 W

1: TRO - ENT-Milan Institute

Segment Length7.509703mi / 12.085700km
Receive LocationENT-Milan Institute
TypeReceiver
Height to Center35.1ft / 10.7m
Antenna MakeRADIO WAVES, INC
Antenna ModelHP2-11
Gain34.5°
Beamwidth3.4°
Location TypeFixed
Location ClassReceive Location
Elevation (AMSL)2,733.3ft / 833.1m
Lat / Lon43-35-26.90 N, 116-17-42.20 W

 

Frequencies and Modulations

FrequenciesToleranceEIRPATPCEmission, Digital Mod Rate, Digital Mod TypeTransmitter MakeTransmitter Model
1: 11385.000000000.00100%53.5dBmN36M2D7W, 142000.0, 32QAM
Dragonwave11HC40HFC277V01HAAM
2: 11385.000000000.00100%53.5dBmN35M8D7W, 181000.0, 64QAM
Dragonwave11HC40HFC277V01HAAM
3: 11385.000000000.00100%53.5dBmN34M4D7W, 212000.0, 128QAM
Dragonwave11HC40HFC277V01HAAM
4: 11385.000000000.00100%53.5dBmN36M7D7W, 277000.0, 256QAM
Dragonwave11HC40HFC277V01HAAM