Path 1 of Microwave License WQPE407
⇠ Return to the list of all paths for Microwave License WQPE407
Path 1:
DAYTON UTILITIES ⇢ DAYTON WATER TANK
Transmit and Receive Locations
DAYTON UTILITIES
Radio Service | MW - Microwave Public Safety Pool |
Transmit Location | DAYTON UTILITIES |
Transmitter Callsign | WQPE407 |
Type | Transmitter |
Height to Center | 29.9ft / 9.1m |
Antenna Make | DRAGONWAVE |
Antenna Model | A-ANT-18G-2-C |
Polarization | V |
Tilt | 0.9° |
Gain | 38.6dBi |
Beamwidth | 3.1° |
Azimuth | 258.8° |
Location Type | Fixed |
Location Class | Transmit Location |
Address | 34 LAKES BLVD |
City | DAYTON |
County | LYON |
State | NV |
Elevation (AMSL) | 4,391.1ft / 1,338.4m |
Height of Structure | 30.2ft / 9.2m |
Overall Height | 30.2ft / 9.2m |
Structure Type | B - Building |
Lat / Lon | 39-14-22.00 N, 119-33-51.40 W |
1: DAYTON UTILITIES - DAYTON WATER TANK
Segment Length | 1.871681mi / 3.012180km |
Receive Location | DAYTON WATER TANK |
Receiver Callsign | WQMK485 |
Type | Receiver |
Height to Center | 20.0ft / 6.1m |
Antenna Make | DRAGONWAVE |
Antenna Model | A-ANT-18G-2-C |
Gain | 38.6° |
Beamwidth | 3.1° |
Location Type | Fixed |
Location Class | Receive Location |
Elevation (AMSL) | 4,559.1ft / 1,389.6m |
Lat / Lon | 39-14-03.00 N, 119-35-54.60 W |
Frequencies and Modulations
Frequencies | Tolerance | EIRP | ATPC | Emission, Digital Mod Rate, Digital Mod Type | Transmitter Make | Transmitter Model |
1: 19440.00000000 | 0.00100% | 55.6dBm | N | 33M1D7W, 50000.0, QPSK
| DRAGONWAVE INC | 18AP40SFC050 |
|