Path 1 of Microwave License WQQG794
⇠ Return to the list of all paths for Microwave License WQQG794
Path 1:
SEYTEC BUD ⇢ COPELAND TWR
Transmit and Receive Locations
SEYTEC BUD
Radio Service | CF - Microwave Common Carrier Fixed Point to Point |
Transmit Location | SEYTEC BUD |
Transmitter Callsign | WQQG794 |
Type | Transmitter |
Height to Center | 49.9ft / 15.2m |
Antenna Make | Commscope |
Antenna Model | VHLP3-11W |
Polarization | V |
Tilt | 0.0° |
Gain | 38.5dBi |
Beamwidth | 1.8° |
Azimuth | 140.0° |
Location Type | Fixed |
Location Class | Transmit Location |
Address | 8825 Bud Jensen Drive |
City | North Richland Hills |
County | TARRANT |
State | TX |
Elevation (AMSL) | 613.2ft / 186.9m |
Height of Structure | 29.9ft / 9.1m |
Overall Height | 49.9ft / 15.2m |
Structure Type | BANT - Building with Antenna on top |
Lat / Lon | 32-51-29.70 N, 097-11-34.40 W |
1: SEYTEC BUD - COPELAND TWR
Segment Length | 9.114269mi / 14.667998km |
Receive Location | COPELAND TWR |
Receiver Callsign | WQHP903 |
Type | Receiver |
Height to Center | 164.0ft / 50.0m |
Antenna Make | Commscope |
Antenna Model | VHLP3-11W |
Tilt | 0.0° |
Gain | 38.5° |
Beamwidth | 1.8° |
Location Type | Fixed |
Location Class | Receive Location |
Elevation (AMSL) | 578.4ft / 176.3m |
Lat / Lon | 32-45-24.80 N, 097-05-32.20 W |
Frequencies and Modulations
Frequencies | Tolerance | EIRP | ATPC | Emission, Digital Mod Rate, Digital Mod Type | Transmitter Make | Transmitter Model |
1: 11505.00000000 | 0.00070% | 62.5dBm | N | 10M0D7W, 50000.0, 128QAM
| CIELO NETWORKS, INC. | SKYLINK-50W-11 |
|