Path 1 of Microwave License WRDC619

⇠ Return to the list of all paths for Microwave License WRDC619

Path 1:   Harlingen 2 ⇢ Harlingen Grain

Transmit and Receive Locations

Harlingen 2

Radio ServiceMG - Microwave Industrial/Business Pool
Transmit LocationHarlingen 2
Transmitter CallsignWRDC619
TypeTransmitter
Height to Center190.0ft / 57.9m
Antenna MakeCambium Networks
Antenna ModelN110082D098
PolarizationV
Tilt0.2°
Gain38.5dBi
Beamwidth2.1°
Azimuth192.9°
Location TypeFixed
Location ClassTransmit Location
AddressUnnamed Road
CityHarlingen
CountyCAMERON
StateTX
Elevation (AMSL)30.8ft / 9.4m
Height of Structure196.9ft / 60.0m
Overall Height200.1ft / 61.0m
Structure TypeLTOWER - Lattice Tower
Lat / Lon26-16-03.80 N, 097-35-02.90 W

1: Harlingen 2 - Harlingen Grain

Segment Length4.821341mi / 7.759198km
Receive LocationHarlingen Grain
TypeReceiver
Height to Center185.0ft / 56.4m
Antenna MakeCambium Networks
Antenna ModelN110082D098
Gain38.5°
Beamwidth2.1°
Location TypeFixed
Location ClassReceive Location
Elevation (AMSL)32.8ft / 10.0m
Lat / Lon26-11-58.10 N, 097-36-05.60 W

 

Frequencies and Modulations

FrequenciesToleranceEIRPATPCEmission, Digital Mod Rate, Digital Mod TypeTransmitter MakeTransmitter Model
1: 10995.000000000.00050%61.5dBmN80M0D7W, 595970.0, 1024QAM
Cambium NetworksPTP11820C
2: 10995.000000000.00050%62.5dBmN80M0D7W, 548020.0, 512QAM
Cambium NetworksPTP11820C
3: 10995.000000000.00050%63.5dBmN80M0D7W, 498680.0, 256QAM
80M0D7W, 433120.0, 128QAM
80M0D7W, 366620.0, 64QAM
80M0D7W, 299600.0, 32QAM
Cambium NetworksPTP11820C
4: 10995.000000000.00050%64.5dBmN80M0D7W, 228240.0, 16QAM
Cambium NetworksPTP11820C
5: 10995.000000000.00050%65.5dBmN80M0D7W, 160140.0, 8PSK
80M0G7W, 112880.0, QPSK
Cambium NetworksPTP11820C