Path 1 of Microwave License WRUQ896

⇠ Return to the list of all paths for Microwave License WRUQ896

Path 1:   MNMW0007 ⇢ MNMW0001

Transmit and Receive Locations

MNMW0007

Radio ServiceCF - Microwave Common Carrier Fixed Point to Point
Transmit LocationMNMW0007
Transmitter CallsignWRUQ896
TypeTransmitter
Height to Center222.8ft / 67.9m
Antenna MakeCOMMSCOPE
Antenna ModelVHLP4-11WA
PolarizationS
Tilt-0.2°
Gain40.7dBi
Beamwidth1.6°
Azimuth167.1°
Location TypeFixed
Location ClassTransmit Location
AddressSouth of: 1241 18th Ave. NW (Austin-009326)
CityAUSTIN
CountyMOWER
StateMN
Elevation (AMSL)1,216.9ft / 370.9m
Tower Registration Number1028550
Height of Structure300.9ft / 91.7m
Overall Height308.1ft / 93.9m
Structure TypeGTOWER - Guyed Structure Used for Communication Purposes
Lat / Lon43-40-55.10 N, 093-00-01.60 W

1: MNMW0007 - MNMW0001

Segment Length7.191183mi / 11.573090km
Receive LocationMNMW0001
TypeReceiver
Height to Center111.9ft / 34.1m
Antenna MakeCOMMSCOPE
Antenna ModelVHLP4-11WA
Gain40.7°
Beamwidth1.6°
Location TypeFixed
Location ClassReceive Location
Elevation (AMSL)1,196.5ft / 364.7m
Lat / Lon43-34-49.50 N, 092-58-06.80 W

 

Frequencies and Modulations

FrequenciesToleranceEIRPATPCEmission, Digital Mod Rate, Digital Mod TypeTransmitter MakeTransmitter Model
1: 10835.000000000.00100%71.7dBmN80M0D7W, 236000.0, 4QAM
SAF TehnikaINTX11_769M_80 ACM
2: 10835.000000000.00100%70.7dBmN80M0D7W, 406000.0, 16QAM
SAF TehnikaINTX11_769M_80 ACM
3: 10835.000000000.00100%70.7dBmN80M0D7W, 508000.0, 32QAM
SAF TehnikaINTX11_769M_80 ACM
4: 10835.000000000.00100%69.7dBmN80M0D7W, 676000.0, 64QAM
SAF TehnikaINTX11_769M_80 ACM
5: 10835.000000000.00100%69.7dBmN80M0D7W, 812000.0, 128QAM
SAF TehnikaINTX11_769M_80 ACM
6: 10835.000000000.00100%68.7dBmN80M0D7W, 946000.0, 256QAM
SAF TehnikaINTX11_769M_80 ACM
7: 10835.000000000.00100%68.7dBmN80M0D7W, 1024000.0, 512QAM
SAF TehnikaINTX11_769M_80 ACM
8: 10835.000000000.00100%67.7dBmN80M0D7W, 1216000.0, 1024QA
SAF TehnikaINTX11_769M_80 ACM
9: 10835.000000000.00100%66.7dBmN80M0D7W, 1344000.0, 2048QA
SAF TehnikaINTX11_769M_80 ACM
10: 10835.000000000.00100%66.7dBmN80M0D7W, 1470000.0, 4096QA
SAF TehnikaINTX11_769M_80 ACM
11: 10835.000000000.00100%66.7dBmN80M0D7W, 1538000.0, 4096QA
SAF TehnikaINTX11_769M_80 ACM