Path 2 of Microwave License WRUQ909

⇠ Return to the list of all paths for Microwave License WRUQ909

Path 2:   MNMW0006 ⇢ MNMW0005

Transmit and Receive Locations

MNMW0006

Radio ServiceCF - Microwave Common Carrier Fixed Point to Point
Transmit LocationMNMW0006
Transmitter CallsignWRUQ909
TypeTransmitter
Height to Center269.0ft / 82.0m
Antenna MakeCOMMSCOPE
Antenna ModelVHLP4-11WA
PolarizationS
Tilt-0.3°
Gain40.7dBi
Beamwidth1.6°
Azimuth315.8°
Location TypeFixed
Location ClassTransmit Location
AddressSE Corner of 680th Avenue and 210th Street; Approximately 1 mile SE of
CityElkton
CountyMOWER
StateMN
Elevation (AMSL)1,405.8ft / 428.5m
Tower Registration Number1249582
Height of Structure399.9ft / 121.9m
Overall Height419.9ft / 128.0m
Structure TypeGTOWER - Guyed Structure Used for Communication Purposes
Lat / Lon43-39-30.10 N, 092-41-19.30 W

1: MNMW0006 - MNMW0005

Segment Length9.455657mi / 15.217409km
Receive LocationMNMW0005
TypeReceiver
Height to Center115.8ft / 35.3m
Antenna MakeCOMMSCOPE
Antenna ModelVHLP4-11WA
Gain40.7°
Beamwidth1.6°
Location TypeFixed
Location ClassReceive Location
Elevation (AMSL)1,350.4ft / 411.6m
Lat / Lon43-45-23.20 N, 092-49-13.70 W

 

Frequencies and Modulations

FrequenciesToleranceEIRPATPCEmission, Digital Mod Rate, Digital Mod TypeTransmitter MakeTransmitter Model
1: 10995.000000000.00100%71.7dBmN80M0D7W, 236000.0, 4QAM
SAF TehnikaINTX11_769M_80 ACM
2: 10995.000000000.00100%70.7dBmN80M0D7W, 406000.0, 16QAM
SAF TehnikaINTX11_769M_80 ACM
3: 10995.000000000.00100%70.7dBmN80M0D7W, 508000.0, 32QAM
SAF TehnikaINTX11_769M_80 ACM
4: 10995.000000000.00100%69.7dBmN80M0D7W, 676000.0, 64QAM
SAF TehnikaINTX11_769M_80 ACM
5: 10995.000000000.00100%69.7dBmN80M0D7W, 812000.0, 128QAM
SAF TehnikaINTX11_769M_80 ACM
6: 10995.000000000.00100%68.7dBmN80M0D7W, 946000.0, 256QAM
SAF TehnikaINTX11_769M_80 ACM
7: 10995.000000000.00100%68.7dBmN80M0D7W, 1024000.0, 512QAM
SAF TehnikaINTX11_769M_80 ACM
8: 10995.000000000.00100%67.7dBmN80M0D7W, 1216000.0, 1024QA
SAF TehnikaINTX11_769M_80 ACM
9: 10995.000000000.00100%66.7dBmN80M0D7W, 1344000.0, 2048QA
SAF TehnikaINTX11_769M_80 ACM
10: 10995.000000000.00100%66.7dBmN80M0D7W, 1470000.0, 4096QA
SAF TehnikaINTX11_769M_80 ACM
11: 10995.000000000.00100%66.7dBmN80M0D7W, 1538000.0, 4096QA
SAF TehnikaINTX11_769M_80 ACM