Paths for Microwave License WRDS894

Paths View paths on FCC.gov

Path 1 - SDPB TOWER ⇢ ROLLING DICE
LocationsTypeLatLon
SDPB TOWER Transmitter 44-03-06.50 N 103-14-38.90 W
ROLLING DICE Receiver 44-09-36.20 N 103-10-18.50 W
FrequenciesToleranceEIRPEmission Code, Digital Modulation Rate, Digital Modulation Type
1: 11565.00000000 V0.00070%52.7dBm56M0D1W, 366000.0, 256QAM
2: 11565.00000000 V0.00070%52.7dBm56M0D1W, 337000.0, 256QAM
3: 11565.00000000 V0.00070%55.7dBm56M0D1W, 289000.0, 128QAM
4: 11565.00000000 V0.00070%55.7dBm56M0D1W, 241000.0, 64QAM
5: 11565.00000000 V0.00070%57.7dBm56M0D1W, 186000.0, 32QAM
6: 11565.00000000 V0.00070%58.7dBm56M0D1W, 145000.0, 16QAM
7: 11565.00000000 V0.00070%59.7dBm56M0D1W, 72000.0, 4QAM